352
Measurement Functions
18.3.3
X-Y Recorder Function
Sampling cycle
1, 10, 100 ms
Recording length
Continuous
Screen and printing
settings
1 screen, 4 screens
Number of X-Y
display
Up to 8 phenomena
X-Y setting
Select 8 channels out of 32 for X axis and Y axis
Interpolation
function
Dot/Line (smooth trace)
Waveform clear
On/Off
Waveform storage
The last 16,000,000 samples of measurement data is retained in internal memory
Pen up/down
Included (all phenomena simultaneously)
External pen control
Controllable by external control terminals (all phenomena simultaneously Up/Down)
Auto-print
None
Manual print*
By pressing the
key (prints up to 50 mm/s, depending on print coverage)
Auto-save
None
* When Model U8350 Printer Unit is installed
18.3.4
FFT Function
Frequency range
133 mHz to 8 MHz, external
Dynamic range
72 dB (theoretical value), 96 dB (theoretical value) when Model 8968 High Resolution Unit
is used
Number of sampling
points
1000 points, 2000 points, 5000 points, 10000 points
Frequency
resolution
1/400, 1/800, 1/2000, 1/4000
Anti-aliasing filters
Coupled with the frequency range, the cutoff frequency is automatically set.
(Only when using the Model 8968 High Resolution Unit)
Analysis channel
setting
Can be selected from desired channels
FFT analysis modes
Storage waveform, linear spectrum*, RMS spectrum*, power spectrum*, cross power
spectrum, auto-correlation function, histogram, transfer function, cross-correlation function,
impulse response, coherence function, 1/1 octave analysis, 1/3 octave analysis, LPC
analysis, phase spectrum
* The total harmonic distortion (THD) is displayed when the cursor display is ON.
Display formats
Single, Dual, Nyquist display, Running spectrum display
Window
Rectangular window, Hanning, Exponential, Hamming, Blackman, Blackman Harris, Flat
top
Display scale
Linear, Log
Print function
Based on the memory function. Note: Sectional printing is not possible.
Peak hold
Included
Averaging
Simple average of time-domain waveform and spectrum, indexed average, peak hold
(frequency axis)
Number of times (2, 4, 8, . . . . to 10,000)
Содержание MR8827
Страница 19: ...14 Operation Precautions ...
Страница 81: ...76 Start and Stop Measurement ...
Страница 111: ...106 Manage Files ...
Страница 125: ...120 Miscellaneous Printing Functions ...
Страница 143: ...138 View Block Waveforms ...
Страница 191: ...186 Setting Output Waveform Parameters ...
Страница 291: ...286 FFT Analysis Modes Measurable Ranges With Octave Analysis 1 1 OCT 1 3 OCT ...
Страница 292: ...287 FFT Analysis Modes 1 1 OCT 1 3 OCT 13 FFT Function ...
Страница 293: ...288 FFT Analysis Modes 1 1 OCT 1 3 OCT ...
Страница 295: ...290 FFT Analysis Modes ...
Страница 309: ...304 Editor Command Details ...
Страница 387: ...382 Module Specifications ...
Страница 405: ...400 Dispose of the Instrument Lithium Battery Removal ...
Страница 431: ...A26 FFT Definitions ...
Страница 436: ......