Appendix 1 Alarm List
363
Appendix
Appendix 1 Alarm List
1.1 Program Alarms (P/S Alarms)
No.
Message
Contents
000
Emergency stop alarm, ESP
input open circuit
Recover ESP signal input to clear alarm.
001
Part prog. open failure
Reset to clear alarm or power-on again.
002
Single block exceeds 256
characters
Characters excessive in single block;
modify the
program.
003
Data exceeds permissive
range
Input data exceeds permissive range, or the specified
data exceeds 8 digits; modify the data.
004
Address not found
With number or symbol other than address at the
beginning of a block. Modify the program.
005
No data follows address
No data follows address or expression format following
address checks error, without brackets. Modify the
program.
006
Illegal use of negative sign
Sign "-" was input after an address with which it can't
be used, or two or more "-" was input. Modify the
program.
007
Illegal use of decimal point
Decimal point"." was input after an address with which
it can't be use, or two or more "." was input. Modify the
program.
008
Input illegal address
Input unusable address in significant area. Modify the
program.
009
Incorrect G code
Specify improper G code or that with functions not
provided. Modify the program.
010
Address repetition error
Specify the same address twice or more in a block, or
specify two or more G codes in same group in a block.
Refer to para. 3403#6 AD2. Modify the program.
011
Command can't run in MDI
mode
Command cannot run in MDI mode. Modify the
program.
012
Too many M codes
Multiple M codes can't be specified in a block, referring
to para.3404#7 M3B. Modify the program.
014
Divided by zero
Divisor was 0(including tan90°). Modify the program.
017
Para. modified failure.
Check that the para. file be abnormal. User partition is
possibly damaged
!
018
Part prog. operation failure
Reset to clear alarm.
019
End of record
Specify end symbol (%) of record, or not specify end of
program, referring to para.3404#6 EOR. Modify the
program.
020
DNC time out
DNC transmission failure; Please check.
021
Feedrate out of range
Feedrate was not commanded to a cutting feed or the
feedrate was inadquate. The meaning of F is
determined by G98/G99, please check current modal
Содержание 988T
Страница 6: ...GSK988T Turning CNC System User Manual VI ...
Страница 14: ...GSK988T Turning CNC System User Manual XIV ...
Страница 15: ...Chapter 1 Programming Fundamentals 1 Ⅰ Programming Ⅰ PROGRAMMING ...
Страница 16: ...GSK988T Turning CNC System User Manual 2 Ⅰ Programming ...
Страница 194: ...GSK988T Turning CNC System User Manual 180 Ⅰ Programming ...
Страница 195: ...Chapter Ⅰ Overview 181 Ⅱ Operation Ⅱ OPERATION ...
Страница 196: ...GSK988T Turning CNC System User Manual 182 Ⅱ Operation ...
Страница 215: ...Chapter Ⅲ Windows 201 Ⅱ Operation Note It can be displayed after U disk is inserted in the U disk catalog ...
Страница 217: ...Chapter Ⅲ Windows 203 Ⅱ Operation ...
Страница 267: ...Chapter Ⅲ Windows 253 Ⅱ Operation Fig 3 51 Fig 3 52 ...
Страница 412: ...GSK988T Turning CNC system User Manual 398 Appendix Fig 3 5 Horizontal operation panel appearance dimension ...