Heating & Air Conditioning
436
MOTOR WILL NOT OPERATE
1. Check the connections to the motor terminals to verify that the (+) positive and (–) negative leads
are connected to the proper supply voltage. If the leads are reversed the unit will not operate. The
motor on a 24 VDC system will not run, but will operate properly when the polarity has been
corrected. Check the circuit breaker to verify that it is functioning properly.
2. Check the motor connections with a voltmeter to verify that the proper voltage is being supplied
to the motor.
3. If the motor has the proper voltage supplied and still does not operate, then there is a problem
with the motor. The motor needs to be serviced by an AMETEK approved service facility or
returned to AMETEK if it is still under warranty.
Содержание LOW FLOOR
Страница 18: ...Specifications 18...
Страница 58: ...Preventive Maintenance 58...
Страница 110: ...Engine 110...
Страница 138: ...Transmission Driveline Rear Axle 138...
Страница 182: ...Suspension 182...
Страница 260: ...Air System 260...
Страница 420: ...Electrical System 420 Deutsch DT Series Connectors...
Страница 421: ...Electrical System 421...
Страница 422: ...Electrical System 422 Deutsch HD 10 Series Connectors...
Страница 423: ...Electrical System 423...
Страница 424: ...Electrical System 424 Deutsch HD 30 Series Connectors...
Страница 425: ...Electrical System 425...
Страница 442: ...Heating Air Conditioning 442...
Страница 486: ...Body and Interior 486 Driver s Seat Troubleshooting Use the following chart to troubleshoot the USSC seat...
Страница 492: ...Body and Interior 492 Figure 11 33 USSC Seat Assembly...
Страница 493: ...Body and Interior 493 Figure 11 34 USSC Seat Suspension Assembly...
Страница 495: ...Body and Interior 495 Figure 11 37 Seat Air Connections...
Страница 506: ...GILLIG CORPORATION 25800 Clawiter Road Hayward CA 94545 Phone 510 785 1500 Fax 510 785 6819 Printed November 2006...