Hydraulic System
333
Possible Cause
Remedy
Problem: Hydraulic fluid milky or white in appearance
Clean vent system or replace cap venting as-
sembly.
A. Water entry through reservoir
system
Possible Cause
Remedy
Problem: Fluid leaking at supply pump
Replace seal
A. Damaged seal
Check operating temperature. Repair pump.
B. Seal damaged by heat
Problem: Hydraulic pump making noise (continued)
Possible Cause
Remedy
Align and replace oil seal and bearings if dam-
aged by shaft misalignment.
C. Coupling misalignment
Leakage between manifold or reservoir at
replenishing hole due to O-ring damage. Reser-
voir inlet tube to pump cover O-ring should be
carefully examined for damage and replaced if
necessary.
D. Reservoir or manifold seal leakage
Possible Cause
Remedy
Problem: Hydraulic fluid forced out of reservoir
Bleed air from system
A. Air in system
Check pump according to instructions in
“Power Steering Hydraulic System Diagnosis”
section.
B. Faulty supply pump (cavitation)
Adjust relief plungers
C. Steering gear relief plungers not
properly adjusted
Check pump according to instructions in
“Power Steering Hydraulic System Diagnosis”
section.
D. Operating temperature high
Содержание LOW FLOOR
Страница 18: ...Specifications 18...
Страница 58: ...Preventive Maintenance 58...
Страница 110: ...Engine 110...
Страница 138: ...Transmission Driveline Rear Axle 138...
Страница 182: ...Suspension 182...
Страница 260: ...Air System 260...
Страница 420: ...Electrical System 420 Deutsch DT Series Connectors...
Страница 421: ...Electrical System 421...
Страница 422: ...Electrical System 422 Deutsch HD 10 Series Connectors...
Страница 423: ...Electrical System 423...
Страница 424: ...Electrical System 424 Deutsch HD 30 Series Connectors...
Страница 425: ...Electrical System 425...
Страница 442: ...Heating Air Conditioning 442...
Страница 486: ...Body and Interior 486 Driver s Seat Troubleshooting Use the following chart to troubleshoot the USSC seat...
Страница 492: ...Body and Interior 492 Figure 11 33 USSC Seat Assembly...
Страница 493: ...Body and Interior 493 Figure 11 34 USSC Seat Suspension Assembly...
Страница 495: ...Body and Interior 495 Figure 11 37 Seat Air Connections...
Страница 506: ...GILLIG CORPORATION 25800 Clawiter Road Hayward CA 94545 Phone 510 785 1500 Fax 510 785 6819 Printed November 2006...