Electrical System
357
requires a momentary surge current which exceeds the rated capacity of the equalizer, Battery A will
supply the extra current to the load. The equalizer will then replenish the energy to Battery A after the
surge has passed.
There are relay contactors internal to the equalizer to prevent damage to the equalizer if the cables are
connected to the wrong terminals. If the cables are connected to the wrong terminals, the relay contac-
tors will open and the equalizer will not turn on. No damage to the unit will occur.
Proper Operation
If the battery equalizer indicator light is ON the equalizer is working.
The equalizer is working properly if:
1. The indicator light is ON and;
2. The 12 volt DC loads are being operated continuously and are within the rated capacity of the
equalizer and;
3. Battery A voltage is lower than Battery B voltage by no more than 0.05 to 0.10 volts (measured
at the equ24, +12, and GND terminals).
The battery equalizer is electronically protected against reverse polarity damage, and therefore the DC
connection sequence is not an issue.
The equalizer will not function properly unless all three battery connections are made. Battery A and
Battery B voltages both must be above 8 volts for the unit to turn ON.
Testing the Battery Equalizer
Equipment Needed:
• DC voltmeter
• DC clamp-on ammeter
Perform the following steps to test the battery equalizer:
1. Field test the equalizer while fully connected to the vehicle batteries. For bench testing, two 12
volt batteries, two 12 volt power supplies are required. The equalizer must be connected to the
batteries at GND, 12V and 24V to function properly.
2. If battery voltage is below 24 volts, start the vehicle or apply a 24 volt battery charger to the bat
-
teries.
3. Turn ON 12 volt DC loads up to the equalizer rated capacity. Measure DC amps on the equalizer
+12 cable to verify load amperages.
4. At the equalizer measure and record:
a. Battery A voltage (voltage between the equ12 and GND terminals)
b. Battery B voltage (voltage between the equ24 and +12 terminals)
c. Equalizer Indicator Light status (ON or OFF)
5. Subtract Battery A voltage from Battery B voltage and compare readings. See table below.
Содержание LOW FLOOR
Страница 18: ...Specifications 18...
Страница 58: ...Preventive Maintenance 58...
Страница 110: ...Engine 110...
Страница 138: ...Transmission Driveline Rear Axle 138...
Страница 182: ...Suspension 182...
Страница 260: ...Air System 260...
Страница 420: ...Electrical System 420 Deutsch DT Series Connectors...
Страница 421: ...Electrical System 421...
Страница 422: ...Electrical System 422 Deutsch HD 10 Series Connectors...
Страница 423: ...Electrical System 423...
Страница 424: ...Electrical System 424 Deutsch HD 30 Series Connectors...
Страница 425: ...Electrical System 425...
Страница 442: ...Heating Air Conditioning 442...
Страница 486: ...Body and Interior 486 Driver s Seat Troubleshooting Use the following chart to troubleshoot the USSC seat...
Страница 492: ...Body and Interior 492 Figure 11 33 USSC Seat Assembly...
Страница 493: ...Body and Interior 493 Figure 11 34 USSC Seat Suspension Assembly...
Страница 495: ...Body and Interior 495 Figure 11 37 Seat Air Connections...
Страница 506: ...GILLIG CORPORATION 25800 Clawiter Road Hayward CA 94545 Phone 510 785 1500 Fax 510 785 6819 Printed November 2006...