![GILLIG LOW FLOOR Скачать руководство пользователя страница 347](http://html1.mh-extra.com/html/gillig/low-floor/low-floor_service-manual_2227483347.webp)
Electrical System
347
Battery Testing
Always wear a face shield, gloves, and protective clothing when servicing
batteries. Lift batteries with handles or proper lifting devices.
Be sure all cables are disconnected from batteries before conducting
tests. See cable disconnect information in the “Disconnecting/Removing
the Batteries” section of this chapter.
Visual inspection alone is not adequate to determine if a battery is serviceable. Following are three ways
to test the batteries in your bus.
Carbon-Pile Load Test
This test may be performed with the battery in or out of the vehicle. This information is provided as a
guideline only. You should follow the instructions of the manufacturer of the carbon-pile load tester.
1. Make sure the battery disconnect switch is in the OFF position. Disconnect battery cables start-
ing with the ground cable.
2. Connect a carbon-pile load tester across the battery.
3. Connect a voltmeter across the battery.
4. If the carbon-pile load tester does not have an accurate built-in ammeter, connect an ammeter in
the carbon-pile load tester circuit.
5. Using the carbon-pile load tester, place a 100 amp load on the battery for 10 seconds to remove
the surface charge.
6. Turn off the carbon-pile load tester and read the open circuit voltage on the voltmeter. It must be
12.4 volts or above. If the voltage reading is below 12.4 volts, charge the battery and start again
at step 1.
7. Using the carbon-pile load tester, place a load equal to one half the battery’s rated Cranking Per
-
formance (specified on the battery) or three times the battery’s 20-ampere-hour capacity, for 15
seconds.
8. The voltage reading must be at least 9.6 volts at the end of the 15 seconds under load.
9. Ensure that both of the batteries have an equal charge before placing the bus in service.
If the battery does not pass the above test, it is not serviceable and should be replaced.
Содержание LOW FLOOR
Страница 18: ...Specifications 18...
Страница 58: ...Preventive Maintenance 58...
Страница 110: ...Engine 110...
Страница 138: ...Transmission Driveline Rear Axle 138...
Страница 182: ...Suspension 182...
Страница 260: ...Air System 260...
Страница 420: ...Electrical System 420 Deutsch DT Series Connectors...
Страница 421: ...Electrical System 421...
Страница 422: ...Electrical System 422 Deutsch HD 10 Series Connectors...
Страница 423: ...Electrical System 423...
Страница 424: ...Electrical System 424 Deutsch HD 30 Series Connectors...
Страница 425: ...Electrical System 425...
Страница 442: ...Heating Air Conditioning 442...
Страница 486: ...Body and Interior 486 Driver s Seat Troubleshooting Use the following chart to troubleshoot the USSC seat...
Страница 492: ...Body and Interior 492 Figure 11 33 USSC Seat Assembly...
Страница 493: ...Body and Interior 493 Figure 11 34 USSC Seat Suspension Assembly...
Страница 495: ...Body and Interior 495 Figure 11 37 Seat Air Connections...
Страница 506: ...GILLIG CORPORATION 25800 Clawiter Road Hayward CA 94545 Phone 510 785 1500 Fax 510 785 6819 Printed November 2006...