Heating & Air Conditioning
43
Safety Precautions
1. Never close the compressor discharge valve while the system is operating.
2. Keep hands clear of the fans and belts when the system is running, especially when opening or
closing the compressor service valves.
3. When working with refrigerant, always wear eye protection; refrigerant can cause severe damage
to the eyes.
4. Never apply heat to a sealed refrigerant system or container.
5. Refrigerant produces phosgene gas when exposed to an open flame. Phosgene gas is hazardous.
It is colorless and is detectable by its unpleasant odor. Phosgene gas can cause severe respiratory
irritation and exposure can be fatal.
6. Exercise caution when working near exposed coil fins. Fins are extremely sharp and could cause
painful lacerations.
Refrigerant Precaution
Although Freon is a safe refrigerant, certain precautions must be observed when handling or servic-
ing any system which uses this cooling medium. If released into the atmosphere when in a liquid state,
refrigerant will evaporate rapidly and will freeze anything it comes in contact with. Frostbite could occur
from exposure to Freon.
Refrigerant Oil Precautions
Synthetic Type:
• In the event of eye contact, immediately flush with water for at least 15 minutes and seek medical
help immediately.
• Avoid prolonged or repeated contact with the skin.
• Wash thoroughly with soap and water after skin contact.
• Wash thoroughly after handling or before eating.
Petroleum Type:
• In the event of eye contact, immediately flush with water for at least 15 minutes and seek medical
help immediately.
• Avoid contact with eyes, skin, and clothing.
• Wash thoroughly with soap and water after skin contact.
• May irritate eyes and skin.
Содержание LOW FLOOR
Страница 18: ...Specifications 18...
Страница 58: ...Preventive Maintenance 58...
Страница 110: ...Engine 110...
Страница 138: ...Transmission Driveline Rear Axle 138...
Страница 182: ...Suspension 182...
Страница 260: ...Air System 260...
Страница 420: ...Electrical System 420 Deutsch DT Series Connectors...
Страница 421: ...Electrical System 421...
Страница 422: ...Electrical System 422 Deutsch HD 10 Series Connectors...
Страница 423: ...Electrical System 423...
Страница 424: ...Electrical System 424 Deutsch HD 30 Series Connectors...
Страница 425: ...Electrical System 425...
Страница 442: ...Heating Air Conditioning 442...
Страница 486: ...Body and Interior 486 Driver s Seat Troubleshooting Use the following chart to troubleshoot the USSC seat...
Страница 492: ...Body and Interior 492 Figure 11 33 USSC Seat Assembly...
Страница 493: ...Body and Interior 493 Figure 11 34 USSC Seat Suspension Assembly...
Страница 495: ...Body and Interior 495 Figure 11 37 Seat Air Connections...
Страница 506: ...GILLIG CORPORATION 25800 Clawiter Road Hayward CA 94545 Phone 510 785 1500 Fax 510 785 6819 Printed November 2006...