Chapter 2: System Description
Data Outputs
The Analyzer has one Ethernet (TCP/IP and Modbus
®
) and three
3
USB ports. Data are output through the USB
ports in text, PDF, and CSV formats, allowing flexibility for exporting and printing data. Historical and diagnostic
data can be transferred from the Analyzer via the USB ports to a USB flash storage device (provided) and then
transferred to any computer that supports USB.
Real-time data can be transferred from the Analyzer via the Ethernet port to a computer using communication
software such as PuTTY
©
, HyperTerminal
®
, and Tera Term
©
. For details, see
"Appendix C: Importing Analyzer
Data also can be transferred through the Ethernet port using Modbus. Details on using
Stream-specific data may be output via 4-20 mA
outputs.
Sample Preparation Device Options
The Analyzer may be configured at the time of purchase to maximize performance by selecting a sample
preparation device most appropriate for the sample to be processed. The following table lists available sampler
configurations.
Clean Water Sample Options
The Clean Water sample options include the 2-Stream Standard (standard or high-temperature option)
configuration and the 5-Stream (standard) configuration. The standard configurations accommodate sample
3.
Three (3) USB ports are provided for your convenience. One is located on the left side of the Analyzer and
the other two are on the System/Controller board. You can only export data from one port at any time.
The Analyzer will export to the first inserted USB flash storage device. While this USB flash storage device
is inserted, the Analyzer will not recognize any additional USB storage devices inserted in other USB ports.
N
OTE
:
The Analyzer MUST be connected to a computer using an Ethernet cross-over cable or to a computer
network using an Ethernet straight-though cable. The Analyzer cannot be directly connected to a
computer via the USB port.
Table 2: Sample Preparation Options
2-Stream
5-Stream
Clean Water Sampler
Standard
Standard
Wastewater Sampler
Optional
(Substitute for Clean Water Sampler)
Optional
(Substitute for Clean Water Sampler)
High Temperature
Sampler
Optional
Not Available
Содержание Sievers Innovox
Страница 214: ...GE Analytical Instruments 2016 214 of 270 DLM 68100 09 EN Rev A Chapter 9 Troubleshooting Figure 88 Analyzer Schematic ...
Страница 235: ...GE Analytical Instruments 2016 235 of 270 DLM 68100 09 EN Rev A Chapter 9 Troubleshooting Figure 104 Reactor Leak Check ...
Страница 248: ...GE Analytical Instruments 2016 248 of 270 DLM 68100 09 EN Rev A Figure 112 Analyzer Dimensions Right Side View ...
Страница 249: ...GE Analytical Instruments 2016 249 of 270 DLM 68100 09 EN Rev A Figure 113 Analyzer Dimensions Left Side View ...
Страница 250: ...GE Analytical Instruments 2016 250 of 270 DLM 68100 09 EN Rev A This page is intentionally left blank ...
Страница 258: ...GE Analytical Instruments 2016 258 of 270 DLM 68100 09 EN Rev A This page is intentionally left blank ...
Страница 264: ...GE Analytical Instruments 2016 264 of 270 DLM 68100 09 EN Rev A This page is intentionally left blank ...
Страница 268: ...GE Analytical Instruments 2016 268 of 270 DLM 68100 09 EN Rev A Index ...
Страница 269: ...GE Analytical Instruments 2016270 269 of 270 DLM 68100 09 EN Rev A Notes ...
Страница 270: ...GE Analytical Instruments 2016270 270 of 270 DLM 68100 09 EN Rev A Notes ...