EXPERT Standard Series User Manual
63
Parameter
code
Parameter
name
Setting range
Mini
munit
Default
value
Mod
ition
F7.21
Braking voltage point 110.0~150.0%
F7.23
Speed display
quotiety
0.001~9.999
F7.24
Linear velocity
quotiety
0.001~9.999
F8 group PID control parameter
F8.00
Closed loop running
control selection
0:No action
1:Action
1
0
×
F8.01
Given channel
selection
0:Number given;
(Refer to F8.06 when F8.02=6; refer
to F8.05 in other conditions)
1:AI1;
2:AI2;
Note:For speed closed loop, analog
given 10V for synchronous speed of
maximum frequency F1.06
1
1
○
F8.02
Feedback channel
selection
0:AI1;
1:AI2;
2:AI1+AI2;
3:AI1-AI2;
4:MIN(AI1,AI2);
5:MAX(AI1,AI2);
6:Pulse;
7:AI3(Expansion card) ;
1
1
○
F8.03
Given channel
smoothing
0.001~50.000s
0.001s 0.500s
○
F8.04
Feedback channel
smoothing
0.001~50.000s
0.001s 0.500s
○
F8.05
Given digital quantity
setting
0.00V~10.00V
0.01
0.00
○
F8.06
Speed closed loop
given
0~39000RPM
1
0
○
F8.07
Pulse encoder every
revolution
1~20000
1
1024
○
F8.08
Minimum given
quantity
0.0%~(F8.10)
(The percentage of minimum given
quantity and reference value
10V;20mA)
0.1%
0.0
○
F8.09
Corresponding
feedback quantity of
minimum given
quantity
0.0~100.0%
(The percentage of corresponding
feedback quantity of minimum given
quantity and reference value
10V;20mA)
0.1%
0.0%
○