EXPERT Standard Series User Manual
80
Parameter
code
Parameter
name
Setting range
Mini
munit
Default
value
Mod
ition
FC.20
Setting running time 0~Max timing 65.535kh
0.001k
h
0
○
FC.21
Reserved
-
-
-
×
FC.22
Power failure restart
function selection
0:No action
1:Action
1
0
×
FC.23
Power-off restart
waiting time
0.0~10.0s
FC.24
Run command
channel binding
frequency given
channel
LED units digit: Frequency channel
selection when keyboard is started or
stopped
0:No binding
1:Keyboard given
2:Terminal UP/DN given
3:Serial port given
4:AI1 analog given
5:AI2 analog given
6:Terminal pulse given
7:Reserved
8:Expansion card AI3 analog
given
LED tens digit:Frequency channel
selection when terminal is started or
stopped
0:No binding
1:Keyboard given
2:Terminal UP/DN given
3:Serial port given
4:AI1 analog given
5:AI2 analog given
6:Terminal pulse given
7:Reserved
8:Expansion card AI3 analog
given
LED hundreds digit:Frequency
channel selection when serial port is
started or stopped
0:No binding
1:Keyboard given
2:Terminal UP/DN given
3:Serial port given
4:AI1 analog given
5:AI2 analog given
6:Terminal pulse given
7:Reserved
8:Expansion card AI3
1
000
○