Table 6-11 Frequency Source Superposition Switching Table
FC.33 unit digit
Terminal invalid
Terminal valid
2
Main frequency source
Auxiliary frequency source
3
Main frequency source
Main and auxiliary
operation results
4
Auxiliary frequency
source
Main and auxiliary
operation results
52: Deceleration and stop input
When this terminal is valid, in any command mode, the running drive will decelerate
and stop.
53: Position reaching input signal
This function is mainly used for positioning deceleration and stop.
54: Special for stop of wire drawing machine
When this function is valid, the drive stops according to acceleration/deceleration time
4, and this function is valid when the percentile of F8.35 is set to 1.
55/56: Left positioning of wire drawing machine cycloid/right positioning of wire
drawing machine
This is a special function of wire drawing machine
F6.09
FWD/REV operation mode
setting
0~3
0
This parameter defines four different ways to control the operation of the drive through
external terminals.
0: Two-wire operation mode 1
1: Two-wire operation mode 2
2: Three-wire operation mode 1