EXPERT Standard Series User Manual
49
Parameter
code
Parameter
name
Setting range
Mini
munit
Default
value
Mod
ition
F0.07
Quick parameters
group display
selection
LED units digit:first parameter
display selection
0: Output frequency
(before compensation)
1: Output frequency
(after compensation)
2: Setting frequency (Hz)
3: Output current(A)
4: Running speed (RPM)
5: Setting speed (RPM)
6: Reserved
7: Reserved
8: Output power (KW)
9: Output torque (%)
A: Output voltage (V)
B: DC bus voltage (V)
C: AI1(V)
D: AI2(V)
E: Analog closed loop feedback
F: Analog closed loop setting
LED tens digit:second parameter
display selection
0~F: ditto
LED hundreds digit:third parameter
display selection
0~F: ditto
LED thousands digit:fourth
parameter display selection
0~F: ditto
0
0x2020
○
F0.08
Double row LED
second line running
display parameter
selection
Display U0 group parameters setting
range:0~16
0
3
○
F1 group Basic operation parameter
F1.00
Control mode
0:Reserved
1:V/F control
2:Sensor-less vector control
3:Sensor vector control
1
1
×
F1.01
Run command
channel selection
0:Keypad command channel
1:Terminal run command channel
2:Serial port run command channel
1
0
○