EXPERT Standard Series User Manual
131
Figure 6-23 Multistage Speed Operation Wiring Diagram
4~5: Acceleration/deceleration time terminal selection
Table 6-7 Acceleration/Deceleration Time Selection Expression
Terminal 2
Terminal 1
Acceleration/deceleration
time selection
OFF
OFF
Acceleration time 1/Deceleration
time 1
OFF
ON
Acceleration time 2/Deceleration
time 2
ON
OFF
Acceleration time 3/Deceleration
time 3
ON
ON
Acceleration time 4/Deceleration
time 4
The ON/OFF combination of acceleration/deceleration time terminals 1 and 2 can
realize the selection of acceleration/deceleration time 1~4.
6 ~ 7: External equipment fault normally on/normally off input
The fault signals of external devices can be input through this terminal, which is
convenient for the drive to monitor the faults of external devices. After receiving a fault
signal from external equipment, the drive displays “E015”, which is the fault alarm of
external equipment. Two input modes of normally on or normally off can be adopted for
fault signals.