EXPERT Standard Series User Manual
128
Content
s
Corresponding function
Contents
Corresponding function
42
Counter zeroing signal input
43
Counter triggering signal input
44
Length count input
45
Pulse frequency input
46
Single phase speed
measurement input
47
Speed measuring input SM1
(only for DI4)
48
Speed measuring input SM2
(only for DI5)
49
Multistage frequency terminal 4
50
Multistage closed-loop given
terminal 4
51
Frequency source switching
52
Deceleration and stop input
53
Position reaching input signal
54
Special for stop of wire drawing
machine
55
Left limit of cycloid of wire
drawing machine
56
Right limit of cycloid of wire
drawing machine
The functions listed in Table 6-5 are introduced as follows: 1 ~ 3, 49: Multistage speed
operation terminals.
By selecting the terminal ON/OFF combination of these functions, you can define up to
16 stages of speed operation curves.
Table 6-6 Multistage Speed Operation Selection Table
K4
K3
K2
K1
Frequency setting
OFF
OFF
OFF
OFF
Normal run frequency
OFF
OFF
OFF
ON
Multistage frequency
1
OFF
OFF
ON
OFF
Multistage frequency
2
OFF
OFF
ON
ON
Multistage frequency
3
OFF
ON
OFF
OFF
Multistage frequency
4
OFF
ON
OFF
ON
Multistage frequency
5