EXPERT Standard Series User Manual
137
Multistage
closed-loop
terminal 4
Multistage
closed-loop
terminal 3
Multistage
closed-loop
terminal 2
Multistage
closed-loop
terminal 1
Multistage closed-loop
given selection
OFF
ON
ON
ON
Multistage closed-loop
given 7
ON
OFF
OFF
OFF
Multistage closed-loop
given 8
ON
OFF
OFF
ON
Multistage closed-loop
given 9
ON
OFF
ON
OFF
Multistage closed-loop
given 10
ON
OF
ON
ON
Multistage closed-loop
given 11
ON
ON
OFF
OFF
Multistage closed-loop
given 12
ON
ON
OFF
ON
Multistage closed-loop
given 13
ON
ON
ON
OFF
Multistage closed-loop
given 14
ON
ON
ON
ON
Multistage closed-loop
given 15
Through the ON/OFF combination of multistage closed-loop terminals 1~4, the
multistage closed-loop given selection in Table 6-10 can be realized.
33: The special tracking function of roll welder
34: Reserved
35: External stop instruction
This command is valid for all run command channels, if this function terminal is valid,
the drive will stop according to F2.08.
36: Forward FWD or run command
37: Reversal REV or forward/reversal direction
38: Drive operation is prohibited
When this terminal is valid, the running drive stops freely, and is prohibited from
starting in standby state. It is mainly used for occasions requiring safety linkage.
39: Length zeroing
When this function terminal is valid, the actual length function code FC.15 is cleared to
zero.