EXPERT Standard Series User Manual
136
When this function terminal is valid, the run command channel is switched to terminal
run command channel by force, and the run command channel is restored after this
function terminal is invalid.
28~29: Run command channel selection 1~2
Table 6-9: Run command channel selection expression
Run command channel
Selection terminal 2
Run command
channel
Selection terminal 1
Run command channel
OFF
OFF
Run command channel hold
OFF
ON
Operation panel run command
channel
ON
OFF
Terminal run command channel
ON
ON
Serial port run command
channel
Through the ON/OFF combination of run command channel selection terminals 1 and
2, the control command selection in Table 6-9 can be realized.
30~32 and 50: Multistage closed-loop terminal 1~4
Table 6-10 Multistage Closed-loop Given Selection Expression
Multistage
closed-loop
terminal 4
Multistage
closed-loop
terminal 3
Multistage
closed-loop
terminal 2
Multistage
closed-loop
terminal 1
Multistage closed-loop
given selection
OFF
OFF
OFF
OFF
The closed-loop given is
determined by F8.01
OFF
OFF
OFF
ON
Multistage closed-loop
given 1
OFF
OFF
ON
OFF
Multistage closed-loop
given 2
OFF
OF
ON
ON
Multistage closed-loop
given 3
OFF
ON
OFF
OFF
Multistage closed-loop
given 4
OFF
ON
OFF
ON
Multistage closed-loop
given 5
OFF
ON
ON
OFF
Multistage closed-loop
given 6