EXPERT Standard Series User Manual
58
terminal 1
31:Multistage closed-loop given
terminal 2
32:Multistage closed-loop given
terminal 3
33:Reserved
34:Reserved
35:External stop command (Effective
to all the control modes, stop
according to the current stop mode)
36:FWD terminal function
37:REV terminal function
38:Drive running prohibited
39:Length reset
40:Auxiliary given frequency reset
41:PLC stop memory reset
42:Counter reset signal input
43:Counter trigger signal input
44:Length counting input (only for
DI4 setting)
45:Pulse frequency input(only for
DI4; DI5 setting)
46:Single phase speed
measurement input(only for DI4
setting)
47:Reserved
48:Reserved
49:Multiple frequency terminals4
50:Reserved
51:Frequency Source switching
52:Deceleration stop command input
53:Position reached input signal(only
for DI4 setting)
F6.05
Multifunction input
terminal DI6
Function selection
3
F6.06
Multifunction input
terminal DI7
Function selection
9
F6.07
Multifunction input
terminal DI8
Function selection
0
F6.08
Expansion card
multifunctional input
terminal DI9 function
selection
0
F6.09
FWD/REV operation
mode setting
0:Two-wire control mode 1
1:Two-wire control mode 2
2:Three-line operation control 1-
self-hold function (additional any
terminal among DI1~DI10)
3:Three-line operation control 2-
self-hold function (additional any
terminal among DI1~DI10)
1
0
×
F6.10
UP/DN rate
0.01~99.99Hz/s
0.01
Hz/s 1.00Hz/s
○