EXPERT Standard Series User Manual
81
Parameter
code
Parameter
name
Setting range
Mini
munit
Default
value
Mod
ition
FC.25
Auxiliary given
channel
0:No action;
1:Keyboard ▲ ▼ given (given by FC.27
directly);
2:Terminal UP/DN given (given by
FC.27 directly);
3:Serial port given (given by FC.27
directly);
4:AI1;
5:AI2;
6:PULSE;
7:-AI1;
8:-AI2;
9:-PULSE
10:AI1-5;
11:AI2-5;
12:PULSE-1/2*F5.03
13:Reserved
14:AI3(Expansion card)
Note:Ineffective when it is the same
with main given channel; frequency of
item 4-9 are used by parameters
confirmed in F5.00
1
0
○
FC.26
Analog auxiliary
given coefficient
0.00~9.99(only for FC.25=4~12)
0.01
1.00
○
FC.27
Figure auxiliary
frequency
0.00~550.0Hz
0.01 0.00Hz
○
FC.28
Figure auxiliary
frequency control
LED units digit:Storage control
0:storage after power off
1:not storage after power off
LED tens digit:
0:stop holding
1:stop reset
Note:Only effective to FC.25=1,2,3
1
000
○
FC.29
Outage time
0~6553.6s
0.1s
10s
○
FC.30
Pulse breakage
detection time
0~6553.6s
0.1s
0s
○