EXPERT Standard Series User Manual
216
0x18
Information frame error: Including information length error and
check error.
0x20
Parameter unable to be modified.
0x22
Parameters are protected by password.
Modify single drive parameter’s application layer protocol data unit, as follows:
Request format is as follows:
Application Layer Protocol
Data Unit
Data Length(Bytes)
Value or Range
Function Code
1
0x06
Register Address
2
0x0000~0xFFFF
Register Content
2
0x0000~0xFFFF
Response format is as follows:
Application Layer Protocol
Data Unit
Data Length(Bytes)
Value or Range
Function Code
1
0x06
Register Address
2
0x0000~0xFFFF
Register Content
2
0x0000~0xFFFF
If operation request fails, response should be error code and abnormal code. Error
code is equal to (function code + 0x80), and see the above description for any
abnormal code.
Application layer protocol data unit of wire diagnosis is as follows:
Request format is as follows:
Application Layer Protocol
Data Unit
Data Length(Bytes)
Value or Range
Function Code
1
0x08
Sub Function Code
2
0x0000~0x0030
Data
2
0x0000~0xFFFF
Response format is as follows: