EXPERT Standard Series User Manual
66
Parameter
code
Parameter
name
Setting range
Mini
munit
Default
value
Mod
ition
F8.43
Differential gain KD 0~9.9(Relative to maximum closed
loop feedback)
0.1%
100%
○
F9 group Simple PLC control parameter
F9.00
Simple PLC running
mode selection
LED units digit:PLC running mode
0:No action
1:Stop after single loop
2:Keep final value after single
loop
3:Continuous loop
LED tens digit: start mode
0:Rerun from the first stage
1:Continue to run from the stage
of halt (or fault)
2:Continue to run from the
stage, frequency of halt (or
fault)
LED hundreds digit: power down
storage
0:No storage
1:Store the stage and frequency
of power down moment
LED thousands digit: stage time unit
selection
0:second
1:minute
1
0000
×
F9.01
Multistage frequency
1
F1.10(lower limit frequency)~
F1.09(upper limit frequency)
0.01Hz 5.00Hz
○
F9.02
Multistage frequency
2
F1.10(lower limit frequency)~
F1.09(upper limit frequency)
0.01Hz 10.00Hz
○
F9.03
Multistage frequency
3
F1.10(lower limit frequency)~
F1.09(upper limit frequency)
0.01Hz 20.00Hz
○
F9.04
Multistage frequency
4
F1.10(lower limit frequency)~
F1.09(upper limit frequency)
0.01Hz 30.00Hz
○
F9.05
Multistage frequency
5
F1.10(lower limit frequency)~
F1.09(upper limit frequency)
0.01Hz 40.00Hz
○
F9.06
Multistage frequency
6
F1.10(lower limit frequency)~
F1.09(upper limit frequency)
0.01Hz 45.00Hz
○