EXPERT Standard Series User Manual
74
Parameter
code
Parameter
name
Setting range
Mini
munit
Default
value
Mod
ition
F9.40
Stage 13 setting
LED units digit:
0:Multistage frequency 13F9.27)
1:Determined by F1.02 function
code
2:Multistage closed loop given
4(F8.32)
3:Determined by F8.01 function
code
LED tens digit:
0:Foreward
1:Reversal
2:Determined by run command
LED hundreds digit:
0:Acceleration and deceleration
time 1
1:Acceleration and deceleration
time 2
2:Acceleration and deceleration
time 3
3:Acceleration and deceleration
time 4
1
000
○
F9.41
Stage 13 running
time
0.0~5500
0.1
0.0
○
F9.42
Stage 14 setting
LED units digit:
0:Multistage frequency
14(F9.28)
1:Determined by F1.02 function
code
2:Multistage closed loop given
4(F8.33)
3:Determined by F8.01 function
code
LED tens digit:
0:Foreward
1:Reversal
2:Determined by run command
LED hundreds digit:
0:Acceleration and deceleration
time 1
1:Acceleration and deceleration
time 2
2:Acceleration and deceleration
time 3
3:Acceleration and deceleration
time 4
1
000
○
F9.43
Stage 14 running
time
0.0~6500.0s
0.1
0.0
○