EXPERT Standard Series User Manual
78
Parameter
code
Parameter
name
Setting range
Mini
munit
Default
value
Mod
ition
FB group Serial port communication parameter
Fb.00
Local address
0:Main Machine address
1~247:Other machine address
1
1
×
Fb.01
Communication
configuration
LED units digit:Baud rate selection
0:1200BPS
1:2400BPS
2:4800BPS
3:9600BPS
4:19200BPS
5:38400BPS
LED tens digit:data format
0:1-8-2-N format, RTU
1:1-8-1-E format, RTU
2:1-8-1-O format, RTU
3:1-7-2-N format, ASCII
4:1-7-1-E format, ASCII
5:1-7-1-O format, ASCII
6:1-8-1-N format,RTU
LED hundreds digit:analog input
terminal
0:Ineffective
1:Effective
LED thousands digit:Change
parameter through write command
06
0:not storage after power off
1:storage after power off
1
0003
×
Fb.02
Reserved
-
-
0
*
Fb.03
Local response delay 0~1000mS
1
5ms
×
Fb.04
Communication
overtime detection
time
0.0~1000s
0.1
0.0s
×
Fb.05
Host routing
00~11
0
11
×
Fb.06
Communication
proportionality
coefficient
0.000~2.000
0.01
1.00
○
FC group Auxiliary function parameter
FC.00
Dynamic braking
selection
0:not allowed
1:allowed
1
1
×
FC.01
Braking usage rate 1~5
1
3
×