Thank you for purchasing the AccuReader 

wafer reading system by LockTech.  This system will 
allow you to read the door/trunk wafers in GM10 cut 
vehicles.  Following a few simple steps it takes only 
minutes to read the depths for each cut in each.  The 
GM10 AccuReader is not designed to be used on the 
newer GM10 cut key commonly referred to as a Z 
key.

The GM10 AccuReader comes with 2 keys. 

One is designed to read any wafers in positions 1-5 
and the other key is designed to read any wafers 
found in positions 6-10.  Using both keys allows for 
reading the more shallow wafer positions with a fully 
or almost fully inserted key, increasing the accuracy. 

The AccuReader works on the process of 

elimination to decipher the correct depths of the lock. 
By checking the deepest cut first you eliminate what 
the cuts are not.  Therefore it is essential to always 
read depth slide #4 first.

Please take the time to familiarize yourself 

with the tools and verify all pieces are accounted for 
from the list of contents below:

Package Contents:
2-AccuReader keys
1-insertion/release slide
1-GM10 depth slide #4
1-GM10 depth slide #3
1-GM10 depth slide #2
1-Tube storage container
1-Tube Cap

USING THE ACCU-READER

1) Always thoroughly clean the lock with a electronics 
safe cleaner to free any potentially stuck wafers. 
Cycle a key blank in and out of the lock approx. 20 
times.

2) Use the alignment holes in the AccuReader key to 
assist in judging the distance from one wafer position 
to the next.  Wafer orientation will vary depending on 
the vehicle.  It is recommended to use a resource 
such as AutoSmart to determine wafer locations for 
specific models.

3) Place the insertion/release slide in the slot on the 
AccuReader key for the 6-10 spaces.  Fully insert the 
AccuReader key into the keyway and remove the 
slide.  Pull the AccuReader outward until a wafer 
traps and note the alignment holes.  Removing the 
AccuReader flipping it over and repeating this step 
will determine if the deepest wafer is on the top or 
bottom.  After this has been determined, Reinsert the 
AccuReader and trap the deepest wafer.  

WHEN 

YOU TRAP A WAFER JIGGLE THE ACCUREADER 
KEY TO INSURE THE WAFER HAS DROPPED 
COMPLETELY TO ITS NORMAL RESTING 
POSITION BEFORE READING.

4) Always

 start reading with the #4 depth slide 

tool, then proceed to #3, then #2 “if necessary.” 

Fully insert the depth slide into the AccuReader key. 
The alignment mark on the depth slide will line up 
with the (

Y

Yes

 mark or it will line up with the (

N

)

 No 

mark.

 

a) If the #4 depth slide lines up with the 

then the depth for that wafer is a 4.  If the depth slide 
lines up with a 

N

, then you must proceed to the #3 

depth slide. 
 

b) If the #3 depth slide lines up with the 

then the depth for that wafer is a 3.  If the depth slide 
lines up with a 

N

, then you must proceed to the #2 

depth slide.

c) If the #2 depth slide lines up with the 

then the depth for that wafer is a 2.  If the depth slide 
lines up with a 

N

, then the depth for that wafer is a 1.

d) Repeat steps a) through c) for each wafer 

position until you have recorded the depths for all 
wafers in positions 6-10.

e) Using the GM10 AccuReader key for 1-5 

spaces repeat a), b), & c) above to read any wafers 
found in positions 1-5.  

Remember when the GM10 

AccuReader key for 1-5 is fully inserted into the 
keyway the wafer trap is aligned with position 5. 

Starting with position 5 continue to read all the 
remaining wafers.

g) You now have recorded all the positions to 

make a working key for that lock.  Progression can be 
used to finish the ignition cuts for a complete key.