Error descriptions
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
Baumüller Nürnberg GmbH
752
5.5
411
Overcurrent EnDat
®
interface
The error is triggered by the module EnDat
®
interface when the
absolute encoder reports via the EnDat
®
interface that the encoder
supply current is too high.
m
Cause:
Cause for a encoder supply current that is too high may be an
internal short circuit.
n
Remedy:
Replace encoder.
Pulse block
412
Battery error EnDat
®
interface
The error is triggered by the module EnDat
®
interface when the Mul-
titurn absolute encoder reports via the EnDat
®
interface that the sup-
ply battery must be replaced. The battery voltage provides position
information for the Multiturn encoder in the memory when the con-
troller is switched off and no supply voltage is provided for the
encoder.
m
Cause:
Cause for a battery replacement in the Multiturn encoder may be
a modification of the battery.
n
Remedy:
Replace encoder.
Pulse block
413
Alarm Bit set
EnDat
®
interface has set alarm Bit (collective message).
Pulse block
414
Error during reception: Address mirror-
ing returns an error
Error during reception: Address mirroring returns an error
Pulse block
415
Variance of encoder signals exceeds
adjustable limit
The variance of encoder signals exceeds adjustable limit
Pulse block
416
Touch probe: trigger zero pulse without
incremental encoder
The touch probe measurement is configured to trigger by a zero
pulse, but the used encoder does not provide a zero pulse.
m
Effect:
Value is not accepted
Response parameterizable
n
Acknowledgment:
No particular action
No response
417
Warning Collision of frequency
EnDat
®
encoder has messaged warning collision of frequency, see
; preventative maintenance is recommended.
No response
418
Warning Excess temperature
EnDat
®
encoder has messaged warning excess temperature; see
and error number 407; preventative maintenance is rec-
ommended.
No response
419
Warning Lighting controller reserve
reached
EnDat
®
encoder has messaged warning „Lighting controller reserve
reached“; see
and error number 406; preventative main-
tenance is recommended in order to avoid lighting failure.
No response
420
Warning Battery load to small
EnDat
®
encoder has messaged warning „Battery load to small“; see
and error number 412; preventative battery change is rec-
ommended.
No response
421
Warning Reference point
EnDat
®
encoder has messaged warning Reference point; see
; preventative maintenance is recommended.
No response
422
Parity errors in received data
Parity errors in the received data of SSI
Pulse block
423
Received data invalid
Received data of SSI encoder are invalid.
Pulse block
428
Encoder monitoring: difference
between analog and digital position too
high
Hiperface encoders: The absolute position is read via the serial hip-
erface interface and compared to the analog position calulated from
the analog SinCos signals by the FPGA. If the position errors abso-
lute value (
) is higher than the defined error threshold
(
) this error is set.
Pulse block
Error
num-
ber
Brief error text
Error description
Default set-
ting for
Error
Response
Содержание b maXX BM2500
Страница 740: ...Monitoring Parameter manual b maXX BM3000 Document no 5 12001 07 Baumüller Nürnberg GmbH 740 of 820 4 11 ...
Страница 814: ...Parameter manual b maXX BM3000 Document no 5 12001 07 Baumüller Nürnberg GmbH 814 of 820 ...
Страница 820: ...Parameter manual b maXX BM3000 Document no 5 12001 07 Baumüller Nürnberg GmbH 820 of 820 Notizen ...
Страница 821: ......