Description of the Software Modules and Parameters
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
275
4
150.10
PT
1
time constant PID controller 1
Time constant of the PT
1
filter in the D leg of the PID controller. If the value „0“ is specified,
the signal will be transmitted unfiltrated.
150.11
Output upper limit PID controller 1
Upper limit of the PID controller output.
If the output is limited with this limit, it will be signalized in
bit 4.
150.12
Output lower limit PID controller 1
Lower limit of the PID controller output.
If the output is limited with this limit, it will be signalized in
bit 4.
150.13
Set value PID controller 1
Value of the set value of the PID controller.
The source of this set value can be selected in
„Source number set value PID
controller 1“.
If the source is not selected (
= 0) the set value can be written via fieldbus or an
analogous input.
If the source is selected (
0) and the value of the source parameter is less than
the minimum value or greater than the maximum value of the set value, the set value is
limited to its minimum or maximum value. This will be signalized in
bit 9.
NOTE!
If the upper limit is greater than the maximum value of the linked target parameter,
then the output is limited at writing on the target parameter to the maximum value of
the linked target parameter if necessary. This will be signalized in
bit 8.
NOTE!
If the lower limit is less than the minimum value of the linked target parameter, then
the output is limited at writing on the target parameter to the minimum value of the
linked target parameter if necessary. This will be signalized in
bit 8.