Description of the Software Modules and Parameters
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
401
4
T
Ramp up
T
Ramp down
= Ramp-down time
Figure 133:
Trapezoidal Profile of Ramp Function Generator
S-Curve Profile
Acceleration and braking are introduced more smoothly with the S-Curve profile.
The time to reach maximum acceleration or deceleration is set using the S-Curve time.
The maximum value of the accelerations is determined by the ramp-up time or the ramp-
down time. The S-Curve time can be set separately for the ramp-up and the ramp-down.
The ramp-up or ramp-down time resulting from a change to the input set value of 100 %
can be found from
T
Ramp-upTotalTime
= T
Ramp-upTime
+ T
SCRamp-upTime
or
T
Ramp-downTotalTime
= T
Ramp-downTime
+ T
SCRamp-downTime
Содержание b maXX BM2500
Страница 740: ...Monitoring Parameter manual b maXX BM3000 Document no 5 12001 07 Baumüller Nürnberg GmbH 740 of 820 4 11 ...
Страница 814: ...Parameter manual b maXX BM3000 Document no 5 12001 07 Baumüller Nürnberg GmbH 814 of 820 ...
Страница 820: ...Parameter manual b maXX BM3000 Document no 5 12001 07 Baumüller Nürnberg GmbH 820 of 820 Notizen ...
Страница 821: ......