Error descriptions
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
Baumüller Nürnberg GmbH
764
5.5
1533
Error while reading sync data of drive
controller
Error when adjusting the synchronization data with the settings in
the drive controller.
No response
1534
Overflow mailbox service
Overflow during a fragmented mailbox service.
No response
1535
Invalid mailbox size
Error detected when checking the mailbox size.
No response
1536 to 1555: see Application Manual SoE slave for BM2500/3300/5000 (5.14010)
1600
wrong driver handle transferred
No response
1601
Open command on already opened
driver
No response
1602
Driver has already been opened
No response
1603
ZERO pointer transferred
No response
1604
Timeout with OS access
No response
1605
Faulty checksum
No response
1606
Response from device faulty
No response
1607
invalid semaphore entered for waiting
No response
1608
unexpected API status for active com-
mand
No response
1609
too many repetitions with Hiperface
®
protocol
No response
1610
Call-up option invalid
No response
1611
unknown object indicated for reading or
writing
No response
1612
Error while initializing the driver
No response
1613
the response data is too large for the
available buffer
No response
1700
Error code directly according to error
report from encoder
Pulse block
1701
Analog signals outside of specification
Calibration data are faulty
Rotary encoder: Analog signals outside of specification
Linear encoder: Calibration data are faulty
Pulse block
1702
Internal angle offset faulty
Pulse block
1703
Table for data field partitioning
destroyed
Pulse block
1704
Analog limit values not available
Pulse block
1705
Internal I2C bus not functional
Pulse block
1706
Internal checksum error
Pulse block
1707
Encoder reset occurred through pro-
gram monitoring
Pulse block
1708
Counter overrun
Pulse block
1709
Parity error
Pulse block
1710
Checksum of transferred data is wrong
Pulse block
1711
Unknown command code
Pulse block
1712
Amount of transferred data wrong
Pulse block
1713
Transferred command argument not
permitted
Pulse block
1714
The selected data field may not be writ-
ten to
Pulse block
1715
Wrong access code
Pulse block
Error
num-
ber
Brief error text
Error description
Default set-
ting for
Error