Error messages and troubleshooting
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
767
5
1931
General transmission error. Client must
repeat telegram (e.g. with fragmented
transmissions)
No response
1932
No additional real time list can be regis-
tered
No additional real time list can be registered
No response
1933
CRC of a transferred file does not
match the calculated file
The files that can be transferred to the device are protected with a
CRC.
During the file transfer through GDP this file CRC is checked in addi-
tion to the separate checksum of the transmission. If it does not
match the calculated checksum, a error will be returned at the end of
the transmission so that this is not detected at the next booting pro-
cedure that the transmission has failed.
No response
1934
Communication partner reports error
number in telegram user data
Communication partner reports error number in telegram user data
The content of the use data must be interpreted as a error number
for further evaluation.
No response
1935
Different subdevice Indices within a
request are not permitted
Parameters within a telegram can only be sent to the same subde-
vice. This error occurs when a client wants to transmit parameters
with different subdevice indices within a telegram.
m
Effect:
The requested telegram cannot be transmitted.
No response
1936
Report timeout has occurred
Report timeout has occurred
No response
1937
Actual data were not picked up on time Actual data (producer data) were not picked up on time
Pulse block
1938
Set value failure at cyclic data
Set value failure at cyclic data
Pulse block
1939
File length smaller than transmitted
data
The file length is smaller than the length of the transmitted data.
More data has been transmitted than the file length should be,
according to the command.
No response
1940
Command is not in the memory of the
command pool
No response
1941
No command data for processing
No response
1943
Error while writing a parameter through
real time
Error while writing a parameter through real time
No response
1944
"Scope" wrong
"Scope" wrong
No response
1946
Available memory in the destination
device insufficient
Available memory in the destination device insufficient
No response
1947
Invalid file name
Invalid file name
No response
1948
Unknown or wrong memory destination
("Destination")
Unknown or wrong memory destination ("Destination")
No response
1949
Unknown option
Unknown option
No response
1950
Wrong file length (e.g. may not be 0)
No response
1951
Connection (TCP/IP, serial) not opened
or closed by the partner
The connection of the transport layer (TCP/IP, serial, ...) is not open.
Either the connection was not opened at all or it was closed due to a
socket error by the internal TCP/IP stack or communication partner.
No response
1952
Data received for a complete telegram
is insufficient
Characters were received through a communication source; how-
ever, the telegram is incomplete and additional characters must be
received.
No response
2200
Error occurred in the FFT module
A error occurred in the FFT Analysis module. For an exact specifica-
tion, refer to Parameter 104.8 "FFT Info".
No response
2201
FFT result not ready for READING yet
No response
Error
num-
ber
Brief error text
Error description
Default set-
ting for
Error
Response