Description of the Software Modules and Parameters
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
709
4
104.2
Status
This parameter shows the current status of the module.
104.3
Signal In 1 source Pxxx
The parameter number for the signal source of Channel 1 can be entered here. Entries
are only possible with the FFT command Stop.
104.4
Signal In 2 source Pxxx
The parameter number for the signal source of Channel 2 can be entered here. Entries
are only possible with the FFT command Stop.
104.6
Signal Out target Pxxx
The parameter for a target parameter can be entered here. The output signal from the
signal generator is thereby routed through the system as an excitation signal. Entries are
only possible with the FFT command Stop.
Status
Meaning
0
Idle
1
Initialization Memory
3
Initialization Window Function
5
Start Average
8
Get Signal Initialization
9
Get Signal
11,12
Windowing Signal Ch1, Ch2
13,15
FFT Ch1, Ch2
17
Standardization
20,22
Auto, Cross Spectrum
24, 25, 26 ÜTF, PHI, Coherence Calculation
28
Check Average
40
FFT result is available for readout
41
Finish