Summary of all Parameters
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
Baumüller Nürnberg GmbH
776
6
Number
Name
Type
Min
Max
Default Value
Unit
Factor
R
ead o
n
ly
St
o
ra
g
e
D
S
Su
pp
ort
C
yclic W
rite
47.45
Rho-RT0
UINT
0
0xFFFF
0
1:1
X
47.46
Delta-Rho in Inc/ I-controller-
clock
INT
-32768
32767
0
1:1
X
47.47
Motor Rho
UINT
0
65535
0
1:1
47.49
Output frequency filtered
FLOAT
-1e9
1e9
0
Hz
2
:1
X
47.50
Dead time compensation
FLOAT
0.0
2.0e+02
0.0
%
1:1
X
47.51
Current controller mode
UINT
0
65535
0
1:1
X
47.52
Iq predicted
FLOAT
-10000
10000
0
A
1:1
X
47.53
Id predicted
FLOAT
-10000
10000
0.0
A
1:1
X
47.54
back emf estimated
FLOAT
-440
440
0
V
1:1
X
47.55
SM Phi error
FLOAT
-180
180
0
Grad
1:1
X
47.65
Current controller cycle time FLOAT
62.50
250.00
62.5
µs
1:1
X
47.70
deadtime voltage ualpha
FLOAT
-440
440
0
V
1:1
X
47.71
deadtime voltage uBeta
FLOAT
-440
440
0
V
1:1
X
52.1
Command status
UINT
0
100
0
1:1
52.2
Mean speed 1
FLOAT
-1000000
1000000
0
Grad/s 1:1
X
52.3
Mean speed 2
FLOAT
-1000000
1000000
0
Grad/s 1:1
X
52.4
Mean Isq 1
FLOAT
-10000
10000
0.00 A
1:1
X
52.5
Mean Isq 2
FLOAT
-10000
10000
0.00 A
1:1
X
52.6
Ks result acceleration
FLOAT
-1.00 1,00E+09
0.00 Grad/
s
2
/A
1:1
X
52.7
Ks result deceleration
FLOAT
-1.00 1,00E+09
0.00 Grad/
s
2
/A
1:1
X
52.8
Ks measured
FLOAT
-1.0
1,00E+09
0
Grad/
s
2
/A
1:1
X
52.9
Load friction factor
FLOAT
-10000
10000
0
A/
Grad/s
1:1
X
52.10
Load friction
FLOAT
-10000
10000
0
A
1:1
X
52.11
Inertia measured
FLOAT
0
1e+9
0
kg cm
2
1:1
X
52.12
Amplitude for FFT
FLOAT
-1e9
1e9
0
1:1
52.15
Kp identification
FLOAT
0
1000000
0
1/s
1:1
X
52.16
Tn identification
FLOAT
0
1000000
0
s
1:1
X
52.17
Phase margin
FLOAT
0
89
60
Grad
1:1
100.1
Error command
UINT
0
65535
0
1:1
X
100.2
Error count
UINT
0
20
0
1:1
X
100.3
Error information
RE-
CORD
X
100.4
Error reaction
RE-
CORD
X
100.5
First error
UDINT
0
5000
0
1:1
X
100.7
Error communication mode
UINT
0
0xFFFF
0
1:1
X
100.8
Error reaction actual value
INT
-5
3
-1
1:1
X
100.9
Error reaction set value
INT
-5
3
-1
1:1
X
100.11
Launch application error
UDINT
0
0xFFFFFFFF 0
1:1
X