4.4
106.70
Encoder excentricity angular phase shift
The phase of the sinusoidal additional angle in order to compensate excentricity or 1st
harmonic.
106.71
Encoder excentricity angular amplitude
The amplitude of the sinusoidal additional angle in order to compensate excentricity or
1st harmonic.
106.72
State of encoder optimization
Status
Meaning
0
Inactive
1
Initialization
2
Measuring for static encoder error correction
3
Measuring for the determination of eccentricity
4
Calculation of amplitude and phase of the measured value
5
Offset correction at static encoder error correction
6
Calculation of amplitude and phase of eccentricity
7
End
8
Error, setpoint frequency not constant
9
Error, setpoint frequency too low
10
Error, setpoint frequency too high
11
Offset error and amplitude error correction active
12 ... 14
Internal calculation
15
Error in calculation
16 ... 21
Internal calculation
22
Acceleration
23
Braking
24
Correction measurement