Description of the Software Modules and Parameters
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
705
4
101.18
Sample time
The sampling time can be entered for all channels. Internal rounding occurs to a whole
number multiple of the control cycle.
101.19
After-run time
The after-running period can be entered for all channels. This is the time during which re-
cording continues after the trigger pulse. This is internally rounded to a whole number
multiple of the sampling time.
It will be ensured that the after-running period is never longer than the recording time.
101.20
Recording time
Total recording time including after-running period. It is calculated from the sampling time,
available memory and number of active channels.
101.21
Buffer size
Display of memory size that is utilized by the ring buffer.
7
Trigger activated through programmable trigger value less than comparison
value
8
Trigger activated because programmable trigger value and comparison
mask different than 0
9
Trigger activated because programmable trigger value and comparison
mask equal to comparison mask
10
Trigger activated because programmable trigger value and comparison
mask equal to 0
Value
Trigger Cause
NOTE!
The after-running period must be at least 300 milliseconds.