Operating Modes
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
Baumüller Nürnberg GmbH
568
4.8
Remark:
m
Bit 1 (Function ended)
The bit is set when the ramp generator has ended its function. Set Values can be out-
put through the signal routing creator (PT
1
link of the trapezoidal cross section).
m
Bit 4 (set value speed = 0)
This bit is set when the set value speed = 0, which means the Positioning module can-
not output new position values. This means, the signal routing creator (PT
1
) must also
be set.
4
1: Set value speed = 0
5
1: Target speed is set to zero
6
1: Target speed > maximum speed; refer to
Speed limit and
7
1: Actual position value was or is within the positioning window (once is suf-
ficient)
8
1: New position data cannot be transferred
9
1: Running positioning stopped
10
1: Set value reached (position destination reached; copy of 108.3 Status
word bit 10)
11
Reserved
12
1: Set value acknowledgment (copy of 108.3 Status word bit 12)
15 … 13 Reserved
16
1: Clip environment 1 reached
17
1: Clip environment 2 reached
18
1: Actual position value >= Clip environment 1
19
1: Actual position value >= Clip environment 2
20
1: Switch position ON (cam ON);
Clip environment 1 <= Act. Pos. value <= Clip environment 2
23 … 21 Reserved
24
1: Drive into negative direction was prevented by revolution direction block
25
1: Drive into positive direction was prevented by revolution direction block
26
1: Drive into negative direction was prevented by hardware position switch
27
1: Drive into positive direction was prevented by hardware position switch
29 … 28 Reserved
30
Positive overrun: Overrunning of maximum position value (= Parameter
) during remaining travel to the destination.
31
Negative overrun: Overrunning of smallest position value (= 0) during
remaining travel to the destination.
Bit no. Meaning