Error descriptions
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
Baumüller Nürnberg GmbH
748
5.5
133
The FPGA has booted the fallback ver-
sion
The FPGA has booted the fallback version
Pulse block
135
Error while programming to flash
Error while programming to flash
No response
137
Time dial computation time overrun
It is being monitored whether the time dials exceed the run time of
MAX_ZS_TIME_LIMIT_IN_TICK = 60 µs too frequently.
Monitoring in remaining time, threshold: per second = 1000*16 ZS,
10% of that: 1600 overruns per second
Pulse block
138
Cycle2 duration too long
Cycle2 duration more than 1% too long in relation to one second.
The CPU is overloaded, computation too great.
Pulse block
139
Drive not synchronous with RT fieldbus
(Warning)
This warning message is issued when the synchronization of the
drive with the fieldbus is activated (Parameter
), but it has
). The message occurs regard-
less of the fieldbus status (operational / not operational) and will be
deleted when the drive is synchronous.
Required for better error diagnosis because the drive cannot be
released when synchronicity is required but has not been achieved.
No response
140
General firmware error, e.g. switch
General firmware error, e.g. switch
Pulse block
141
Operating system error
Error in context with the operating system
Pulse block
142
Method not implemented
Method not implemented
Pulse block
144
invalid file type
invalid file type
No response
145
File already open
File already open
No response
146
Maximum size of file reached (writing
reading)
Maximum size of file reached (writing reading)
No response
147
File not opened
File not opened
No response
148
File not opened for this access (Read
Write access)
File not opened for this access (Read Write access)
No response
149
Indicated ID wrong
Indicated ID wrong
No response
150
Indicated index does not exist (too
large)
Indicated index does not exist (too large)
No response
151
Parameter element cannot be written
Parameter element cannot be written
No response
152
External access not permitted
External access not permitted
No response
153
Value less minimum value
Value less minimum value
No response
154
Value greater maximum value
Value greater maximum value
No response
155
Value errory
Value errory
No response
156
Value cannot be changed due to the
operating condition
Value cannot be changed due to the operating condition
No response
157
wrong axis index
wrong axis index
No response
158
Format information wrong
Format information wrong
No response
159
Error while reading system data
Error while reading system data from flash
No response
168
No write permission for the actual
access level
Parameter cannot be changed due to the access protection. No
write permission for the actual access level.
No response
169
Application error to test the error
responses
Application error to test the error reactions. The error is enabled by
value 5 on parameter 100.1 Info-Manager Error command for one
single time. The error can be used to test the different error reactions
without having to enable a „real“ error, e.g. return.
No response
Error
num-
ber
Brief error text
Error description
Default set-
ting for
Error
Response