![Baumuller b maXX BM2500 Скачать руководство пользователя страница 337](http://html.mh-extra.com/html/baumuller/b-maxx-bm2500/b-maxx-bm2500_operating-manual_2711400337.webp)
Description of the Software Modules and Parameters
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
337
4
n
Action:
m
None
8 OPERATION ENABLED
DRIVE SHUT-DOWN ACTIVE
n
Event:
m
"Shut Down" command or
m
Pulse enable input = Low
n
Action:
– Drive activation by control word:
m
Drive shut-down is initiated (braked or coast-down, depending on setting, or coast
down if Pulse enable input = Low)
8a DRIVE SHUT-DOWN ACTIVE
READY TO SWITCH ON
n
Event:
m
SHUT-DOWN response (
) is set to "Inhibit Drive Function" (Pulse Inhib-
it, value 0) or
m
Drive Shut-down has ended (speed 0 reached)
m
Pulse enable input = Low
n
Action:
m
Drive function is inhibited
9 OPERATION ENABLED
SWITCH-ON INHIBIT
n
Event:
m
"Inhibit Voltage" command
n
Action:
m
Drive function is inhibited
10 SWITCHED ON
SWITCH-ON INHIBIT
n
Event:
m
"Inhibit Voltage" command or
m
"Quick Stop" command or
m
Quick Stop input = Low (only if Quick Stop (QS) hardware control input is used)
n
Action:
m
Drive function is inhibited
11 OPERATION ENABLED
QUICK STOP ACTIVE
n
Event:
m
"Quick Stop" command or
m
Quick Stop input = Low (only if Quick Stop (SH) hardware control input is used)
n
Action:
m
Quick Stop is initiated (braked or coast-down, depending on setting)