231
4
Deactivation of the "Test input" is done in two ways:
m
by deactivating the "Test input on/off" check box; Parameter 125.1 or 125.2 should
then be set to 0. As a result, the value 0 appears in the corresponding "Source Param-
eter Number" box.
m
by directly writing a different ID in the "Source Parameter Number" box. The corre-
sponding check box must also be automatically deactivated.
4.4.13.3 Parameter overview
Functional block:
FbVisu [125]
Number
Name
Type
Min
Max
Default Value
Unit
Factor
Read
on
ly
St
o
ra
g
e
D
S
Su
pp
or
t
Cyclic W
rite
125.1
Visu Channel 1 source
parameter id
UDINT
0
4294967295
0
1:1
X
125.2
Visu Channel 2 source
parameter id
UDINT
0
4294967295
0
1:1
X
125.3
Visu command
UINT
0
1
0
1:1
X
125.4
Visu status
UINT
0
1
0
1:1
X
125.7
Visu task no
UINT
0
3
3
1:1
X
125.8
General scaling
FLOAT
-5000000000
5000000000
1.00 Unit/V 1:1
X
125.9
Force scaling
FLOAT
0
2147483648
1.00 N/V
1:1
X
125.10
Current scaling
FLOAT
-5000000000
5000000000
1.00 A/V
1:1
X
125.11
Voltage scaling
FLOAT
-5000000000
5000000000
1.0
V/V
1:1
X
125.12
Position scaling
FLOAT
-5000000000
5000000000
3.01 Unit/V 1:1
X
125.13
Speed scaling
FLOAT
-5000000000
5000000000
1.03 Unit/V 1:1
X
125.14
Acceleration scaling
FLOAT
-5000000000
5000000000
4
Unit/V 1:1
X
125.15
Torque scaling
FLOAT
-5000000000
5000000000
1
Nm/V
1:1
X
125.17
Test Signal amplitude
FLOAT
0
5000000000
0
V
1:1
125.18
Correction gain channel 1
FLOAT
0
5000000
1.000
1:1
X
125.19
Correction gain channel 2
FLOAT
0
5000000
1.000
1:1
X
125.20
Offset channel 1
FLOAT
-10.0
10.0
0
V
1:1
X
125.21
Offset channel 2
FLOAT
-10.0
10.0
0
V
1:1
X
125.22
Test signal
FLOAT
-5000000000
5000000000
0
V