Performing the commissioning
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
Baumüller Nürnberg GmbH
58
3.6
3.6
Performing the commissioning
Begin the commissioning after you have completed the preparations.
1
Connect the power supplies to the b maXX
®
(main power control voltage).
The device then starts up and indicates that it is ready for operation by lighting the
orange 'Power ON' LED H12.
m
LED H12 must light up orange; this signifies Power ON and the device is ready for
operation.
m
LED H12 must not light up green: when LED H12 lights up green, it means "Opera-
tion enabled"! The motor is supplied with current and can rotate! Override this im-
mediately with the pulse enable switching element!
m
LED H13; a red LED means that the current limit has been reached. Reduce the
loading on the motor. Continue with the parameter setting.
m
LED H14; a red LED indicates a error condition. Rectify the error later using the
ProDrive operating program. Continue with the parameter setting.
2
Establish communication as described in
3
Start the ProDrive program (if it is not already running).
4
Then click on auf "Drive Manager" in ProDrive
Figure 41:
ProDrive: Navigation Drive manager
Acknowledging
warnings/errors
5
"Acknowledge" any warnings/errors that may be present in the "Drive manager" win-
dow (press the "Reset errors" button several times if necessary).
NOTE
Any queued error messages may result from the as yet incomplete parameter setting.
These errors cannot be acknowledged.