![Baumuller b maXX BM2500 Скачать руководство пользователя страница 261](http://html.mh-extra.com/html/baumuller/b-maxx-bm2500/b-maxx-bm2500_operating-manual_2711400261.webp)
Description of the Software Modules and Parameters
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
261
4
124.2
Activation command
Command to delete one or more measurements. The following actions will be performed
for the corresponding channel:
m
Deleting the associated status bit (measurement occurred / not occurred) in status
m
Setting measured values of individual channels to zero
m
Reactivation of an already (through Parameter 124.1) activated channel
Toggling the corresponding bit will trigger the command.
The parameter can be used to delete the indexes / latched values of the measuring en-
coder during active operation, but the application is not necessary
9
Activation Qualification with digital input
0: Qualification off
1: Qualification on
10
Selection digital input for qualification
0: Qualification zero pulse with digital input TP1
1: Qualification zero pulse with digital input TP2
11
Selection Signal Level for qualification
0: Zero pulse trigger active when digital input = low
1: Zero pulse trigger active when digital input = high
12
Trigger frequency
0: one-time trigger
a new measure does not occur until measuring encoder has been reac-
tivated with P124.2
1: Continuous triggering
Measurements always occur; however, within a sampling cycle of the
module (1 ms), only the first event will be triggered.
13…14
Reserved
15
Activation filter 500 µs for measuring encoder digital input TP1 (effects
only for measuring encoder, to all encoder)
1: Filtering with 500 µs
0: No filtering (-> 4 µs)
16… 29
Reserved
30
For all channels:
0: Delete measuring values, if channel is switched on
1: Delete measuring values, if channel is switched off
31
Reserved
Bit
Meaning