![Baumuller b maXX BM2500 Скачать руководство пользователя страница 547](http://html.mh-extra.com/html/baumuller/b-maxx-bm2500/b-maxx-bm2500_operating-manual_2711400547.webp)
Description of the Software Modules and Parameters
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
547
4
121.25
Monitoring window positive stop
The stop at the positive stop is monitored with the monitoring window. The reference is
the stored value in
Positive stop position.
The drive generates an error if the position actual value is outside of this positive stop win-
dow. The parameter setting should not disturb the correct positive stop procedure. The
monitoring should detect a break or deformation of the positive stop.
The monitoring can be enabled via
Mode positive stop drive bit 0-1 = 01.
121.26
Offset modulo position actual value
By this offset the parameter
modulo position-actual value can be moved.
121.27
Command value mode
This parameter determines the rotational direction of the modulo function.
Bit
Meaning
0 ...1
Rotation direction at Modulo function
00: Positive rotational direction
01: Negative rotational direction
10: Shortest way (path optimized)
11: Normal (just as linear, not exceeding the modulo range)
15 ... 2
Reserved
NOTE!
This setting is for the rotational direction of the modulo function in the operating mode
"Position control with synchronous position set value setting" (-4) relevant.
target mode is effective in the target position setting (1) oper-
ation mode!
The values in the bits 0 and 1 in the
mode is effective in the spindle posi-
tioning (-6) operation mode.