![Baumuller b maXX BM2500 Скачать руководство пользователя страница 90](http://html.mh-extra.com/html/baumuller/b-maxx-bm2500/b-maxx-bm2500_operating-manual_2711400090.webp)
System
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
Baumüller Nürnberg GmbH
90
4.3
4.3.2
Display
4.3.2.1 Parameter overview
Functional block:
FbDisplay [135]
4.3.2.2 Description of the Parameters
135.1
Mode Error Display
Number
Name
Type
Min
Max
Default Value
Unit
Factor
Read
on
ly
St
o
ra
g
e
D
S
Su
pp
or
t
Cyclic W
rite
135.1
Mode error display
UDINT
0
0xFFFFFFFF 0x1010000
1:1
X
Bit
Value
Meaning
15 ... 0
Reserved
23 ... 16
0
Only errors (with a response set in the parameters) are displayed:
the error-LED H14 (axis 1) or H24 (axis 2) is on in case of error.
If only warnings or errors without a response set in the parameters
are triggered, the error-LED flashes
1
All errors and warnings are displayed; the error-LED is on perma-
nently in case of error or warning.
24
Activation of LED Power On (H12 (axis 1) or H22 (axis 2), if power
on
0
LED is on permanently
1
LED flashes (life signs)
31 ... 25
Reserved