![Baumuller b maXX BM2500 Скачать руководство пользователя страница 387](http://html.mh-extra.com/html/baumuller/b-maxx-bm2500/b-maxx-bm2500_operating-manual_2711400387.webp)
Description of the Software Modules and Parameters
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
387
4
4.5.4.2 Description of the Parameters
100.1
Error Command
Command for the Info Manager.
100.2
Error Count
Returns the number of errors present in the error memory since the last switch-on or since
the last error reset.
Number
Name
Type
Min
Max
Default Value
Unit
Factor
Rea
d
on
ly
St
o
ra
g
e
DS Su
ppo
rt
Cyc
lic W
rite
100.1
Error command
UINT
0
65535
0
1:1
X
100.2
Error count
UINT
0
20
0
1:1
X
100.3
Error information
RE-
CORD
X
100.4
Error reaction
RE-
CORD
X
100.5
First error
UDINT
0
5000
0
1:1
X
100.7
Error communication mode
UINT
0
0xFFFF
0
1:1
X
100.8
Error reaction actual value
INT
-5
3
-1
1:1
X
100.9
Error reaction set value
INT
-5
3
-1
1:1
X
100.11
Launch application error
UDINT
0
0xFFFFFFFF 0
1:1
X
Value
Meaning
0
Reserved
1
Reset all errors
Parameter is supported for compatibility reasons, use instead of that
Control Word 1 bit 7 as far as possible
2
Reset all error responses to the default values
4
Reset all errors
Parameter is supported for compatibility reasons, use instead of that
Control Word 1 bit 7 as far as possible
5
Trigger application error no. 169
6
Reset error memory
Remain-
der
Reserved
Содержание b maXX BM2500
Страница 740: ...Monitoring Parameter manual b maXX BM3000 Document no 5 12001 07 Baumüller Nürnberg GmbH 740 of 820 4 11 ...
Страница 814: ...Parameter manual b maXX BM3000 Document no 5 12001 07 Baumüller Nürnberg GmbH 814 of 820 ...
Страница 820: ...Parameter manual b maXX BM3000 Document no 5 12001 07 Baumüller Nürnberg GmbH 820 of 820 Notizen ...
Страница 821: ......