Operating Modes
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
Baumüller Nürnberg GmbH
628
4.8
Other functions:
m
Optional speed synchronization of the slave axis with the master axis is possible when
the synchronous operation is activated. For details, refer to Parameter
Mode
Bit 8.
m
Speed synchronization with Online operating mode changeover (Status Operation En-
abled) from synchronous operation to another position or speed controlled operating
mode. The speed synchronization must be activated for the operating mode.
m
Stop command possible through control word Bit 8. A speed synchronization with the
master speed may occur after the Stop has been canceled.
m
Integrated Ramp generator with profile data in master axis resolution. The setting is en-
tered in Parameters
to
. A selection between speed profiles Trape-
zoidal or S-Curve is possible. The ramp generator becomes active during speed
synchronization, with a Stop command or with the virtual master axis.
m
Virtual master axis without ramp generator (ramp function generator) with optional in-
terpolation of set value cycle to control cycle. This mode is activated in Parameter
Mode Bit 12 = 1.
The interpolation cycle setting for the set value speed (
Virt. lead speed set
value) is entered in
. Interpolation does not occur with a value of 1 ms and
the
is directly (not interpolated) transferred to the transmission input). The
parameter may also be a multiple of the fieldbus cycle, such as fieldbus cycle = 2 ms
and set value cycle = 6 ms. In the example this means that the control must only send
a newly calculated speed set value to the controller every third fieldbus cycle.
m
Monitoring of speed synchronization between master and slave axis.
Status Bit 8 displays exiting the
Synchronization velocity window of
the slave axis.
m
There are two additional inputs (
and
) besides the main set value
or the master axis position, if the master axis is virtual or real.