Description of the Software Modules and Parameters
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
395
4
4.5.6.1 Parameter overview
Functional block:
SwgManager [111]
4.5.6.2 Description of the Parameters
111.1
Status
For all speed and position controlled operating modes in the OPERATION ENABLED
state, the set value manager is switched on.
In operating modes such as, e.g., current control it thus remains switched off.
Number
Name
Type
Min
Max
Default Value
Unit
Factor
Read
on
ly
St
o
ra
g
e
D
S
Su
pp
ort
Cyclic
W
rite
111.1
Status
WORD
0x0000
0xFFFF
0x0000
1:1
X
111.2
Position set value rev
UDINT
0
0xFFFFFFFF 0
Inc
1:1
X
111.3
Position set value angle
UDINT
0
0xFFFFFFFF 0
Inc
1:1
X
111.4
Speed set value
DINT
0x80000000
0x7FFFFFFF
0
Inc/ms 1:1
X
111.5
Acceleration set value
DINT
0x80000000
0x7FFFFFFF
0
Inc/
ms²
1:1
X
111.6
Interpolation mode
UINT
0
4
1
1:1
X
X
111.7
External speed feedforward
FLOAT
-180000
180000
0
Grad/s 1:1
X
111.8
External acceleration feed-
forward
FLOAT
-2147483647
2147483647
0
Grad/
s
2
1:1
X
111.9
Jerk set value
DINT
0x80000000
0x7FFFFFFF
0
Inc/
ms
3
1:1
X
Bit no.
Meaning
0
0: Set Value manager is switched off
1: Set Value manager is switched on; the set value sources provide set val-
ues to the set value manager
3 … 1
Reserved
4
1: Set Value setting by RT1 Task active; fixed cycle time of 1 ms
5
1: Set Value setting by Fieldbus Task active; configurable cycle time
15 … 6
Reserved