Configuration
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
Baumüller Nürnberg GmbH
94
4.4
4.4.1.3 Description of the Parameters
129.3
Hardware Id
The hardware identifier has the format:
33.YYNN.[S]BB.A.01
Example: 33.1110.S01.C.01
130.25
Mains failure delay
UINT
0
6000
0
ms
1:1
X
130.29
Chopper threshold
FLOAT
400
780
780
V
1:1
X
130.34
Status STO module
UINT
0
0xFFFF
0
1:1
X
130.35
Mains failure detection mode UDINT
0
0xFFFFFFFF 0
1:1
X
130.36
Relative Udc threshold for
mains failure
FLOAT
10
90
80
%
1:1
X
130.37
Udc threshold for mains fail-
ure
FLOAT
10
1000
450
V
1:1
X
130.38
Udc hysteresis for mains fail-
ure
FLOAT
10
500
50
V
1:1
X
130.39
Udc autodetect
FLOAT
0
1000
0
V
1:1
X
130.41
Actual PWM frequency
UINT
2
16
8
kHz
1:1
X
175.3
Max. device control cabin
temperature
UINT
0
55
40
Grad
C
1:1
X
175.4
Max. device altitude
UINT
0
5000
1000
m
1:1
X
175.5
Max. device mains voltage
UINT
0
530
400
V
1:1
X
175.6
Max. device DC link voltage
UINT
0
760
540
V
1:1
X
175.7
PU max.continuous current
actual value
FLOAT
0
1000
4
A
1:1
X
175.8
PU I2t max. continuous cur-
rent actual value
FLOAT
0
1000
4
A
1:1
X
Abbreviation
Meaning
YY
Year
Example: 20
11
NN
Sequential number
Example:
10
S
STO module available
BB
Assembly variant
Example:
01
A
Revision number
Example:
C
01
Technical status
Example:
01
Содержание b maXX BM2500