4.7
47.52
Iq predicted
This parameter displays the predictive current Iq determined by the current prediction pro-
cedure, if the current prediction procedure is switched on.
47.53
Id predicted
This parameter displays the predictive current Id determined by the current prediction pro-
cedure, if the current prediction procedure is switched on.
47.54
Back EMF estimated
EMF acting in the q-direction. Required for field angle monitoring of PMSM.
Bit
Meaning
0
Switches the current prediction for the current controller on/off:
0: Current prediction deactivated
1: Current prediction active
1
Feedforward of the ohmic voltage drop at the stator winding (IxR feedfor-
ward):
0: IxR feedforward deactivated
1: IxR feedforward active
2
Selection of the actual current or set value current for the feedforward of
the ohmic voltage drop:
0: Using the actual current value for IxR feedforward
1: Using the current set value for IxR feedforward
3
Reserved
4
0: Udc-Id controller off
1: Udc-Id controller on
5
0: Short circuit brake off
1: Short circuit brake on
6
Reaction when exceeding the threshold for the reactive current brake.
0: Id target = Id max
1: Increase of Id via Udc link-Id controller
15 ... 7
Reserved