Error messages and troubleshooting
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
765
5
1716
Indicated data field size cannot be
changed
Pulse block
1717
Indicated word address is outside of
the data field
Pulse block
1718
No data field or addressed data field
does not exist
Pulse block
1728
Amount monitoring for analog signals
(process data)
Amount monitoring for analog signals (process data)
Pulse block
1729
Transmission current critical (contami-
nation, transmission break)
Transmission current critical (contamination, transmission break)
Pulse block
1730
Encoder temperature critical
Encoder temperature critical
Pulse block
1731
Speed too high, no position establish-
ment possible
Speed too high, no position establishment possible
Pulse block
1732
Speed too high, position can't be calcu-
lated
At rotatory encoders:
m
position can't be calculated
At linear encoders:
m
sensor is not adjusted or is not in adjustment mode
Pulse block
1733
Position error
At rotatory encoders:
m
Position error Multiturn
At linear encoders:
m
distance magnetic tape/sensor too high
Pulse block
1734
Position error
At rotatory encoders:
m
Position error Multiturn
At linear encoders:
m
Positional error
Pulse block
1735
Position error Multiturn
Position error Multiturn
Pulse block
1752
Error while initializing the encoder
(multiple errors)
Error while initializing the encoder (multiple errors)
Pulse block
1753
Position generally not dependable
Encoder position not dependable. Quotient of resolution to line num-
ber faulty
Pulse block
1754
Unknown error from encoder
Unknown error code from the encoder
Pulse block
1800
no or invalid data in the encoder motor
type plate
The error occurs when no motor data can be read from the encoder
after rebooting.
Pulse block
1801
Invalid section found in the encoder
OEM memory
Invalid section found while reading the encoder memory. Reference
to wrong data in the OEM memory of the encoder.
Pulse block
1802
too many sections of the type "variable
operating data"
Pulse block
1803
Index for addressing the section for
variable operating data too large
Pulse block
1805
Checksum error in Section
Pulse block
1806
Version of imported data structure
unknown
Pulse block
1808
Wrong quantity (0 or 128)
Pulse block
1809
Wrong data field (only 0 or 1 permitted)
Pulse block
1810
Data field start address too large (=
128)
Pulse block
1813
No memory available in the encoder
Pulse block
1814
Faulty data in the section
Data in the section is not plausible (WordCount is 0 or too large)
Pulse block
Error
num-
ber
Brief error text
Error description
Default set-
ting for
Error
Response
Содержание b maXX BM2500
Страница 740: ...Monitoring Parameter manual b maXX BM3000 Document no 5 12001 07 Baumüller Nürnberg GmbH 740 of 820 4 11 ...
Страница 814: ...Parameter manual b maXX BM3000 Document no 5 12001 07 Baumüller Nürnberg GmbH 814 of 820 ...
Страница 820: ...Parameter manual b maXX BM3000 Document no 5 12001 07 Baumüller Nürnberg GmbH 820 of 820 Notizen ...
Страница 821: ......