background image

Flow Monitor

B3100 Series Data Logging

DSY-UM-02260-EN-01 (April 2017)

User Manual

Содержание Blancett B3100 Series

Страница 1: ...Flow Monitor B3100 Series Data Logging DSY UM 02260 EN 01 April 2017 User Manual...

Страница 2: ...N 01 April 2017 NOTICE This User Manual is meant as a quick reference document and is an addendum to the documentation set that came with the B3100 This User Manual assumes that the B3100 is installed...

Страница 3: ...DSY UM 02260 EN 01 April 2017 Blancett B3100 Flow Monitor Datalogging Page 3...

Страница 4: ...7 3 DESCRIPTION 7 3 1 Functional description 7 3 2 Component information 7 3 2 1 The interval records 7 3 2 2 The daily records 8 3 2 3 The event records 8 4 OPERATION 8 4 1 1 The interval log 8 4 1 2...

Страница 5: ...sing 1 1 About this User Manual This User Manual is written with the use of the guidelines for Simplified Technical English ASD STE100 Simplified Technical English has an own set of grammar and a limi...

Страница 6: ...0 2 2 Operational menu structure NOTICE The in the menu name represents the sequence number of the record MENU MENU ITEM SETTING DATALOG INTERVAL Empty or recorded interval data A Rate B Total C Accum...

Страница 7: ...re also two possibilities to review the logged data You can review the logged data on the B3100 themselves or if installed via communication through the explosion proof installed USB connector and the...

Страница 8: ...cords the performance of the B3100 and the measured medium that passed the sensor e g flowmeter with respect to the time and the date The interval and daily records are logged as programmed in the set...

Страница 9: ...sly The setup menu DATALOG shows Press the button as many times as applicable 3 Press the button to find the LOG INT menu item The LOG INT menu item shows Press the button as many times as applicable...

Страница 10: ...u do not press the PROG button to confirm your selection is not saved 7 Press the button to find the DAILY 1 menu item The DAILY 1 menu item shows In this menu item the time for the creation of the re...

Страница 11: ...nds The SETUP indicator comes on continuously The setup menu TOTAL shows To enter the setup menu 2 Press the button to find the DATALOG menu The SETUP indicator stays on continuously The setup menu DA...

Страница 12: ...e DATALOG menu shows The RUN indicator stays on The LOG indicator comes on In the background the B3100 stays operational 2 Press the button to find the INTERVAL log The INTERVAL log shows Press the bu...

Страница 13: ...mes on The latest daily record shows with the date the sequence number and the time The trend down indicator indicates that the latest record is shown Press the button to view the earlier records 4 Pr...

Страница 14: ...t steps are only applicable for the setup menu related events Each setup menu item has a Modbus address Other events e g clear total do not have a Modbus address and therefore the next records cannot...

Страница 15: ...terials and equipment from the work area 4 Make sure the work area is clean 5 Dispose of the electronic waste in accordance with the inter national the manufacturer s and the plant owner s standards a...

Страница 16: ...lina N 24 Colonia Guadalupe Inn CP 01050 M xico DF M xico 52 55 5662 0882 Europe Eastern Europe Branch Office for Poland Latvia Lithuania Estonia Ukraine Belarus Badger Meter Europe ul Korfantego 6 44...

Отзывы: