![Baumuller b maXX BM2500 Скачать руководство пользователя страница 686](http://html.mh-extra.com/html/baumuller/b-maxx-bm2500/b-maxx-bm2500_operating-manual_2711400686.webp)
Operating Modes
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
Baumüller Nürnberg GmbH
686
4.8
122.16
Master standstill threshold
The standstill threshold is specified to monitor if the master axis stands still during the
synchronization phase.
122.17
Target position offset
The parameter specifies the target position for the overlaid compensating movement
during operation. The parameter has the following format:
122.18
Maximum speed offset
The value of this parameter in Inc/ms specifies the maximum speed of the overlaid com-
pensating movement during the active operation, by which the drive overlays the polyno-
mial curve.
The resolution is 16 bit increments/revolution per ms.
122.19
Maximum acceleration offset
The value of this parameter in Inc./ms
2
specifies the maximum acceleration of the over-
laid compensating movement during the active operation by which the drive overlays the
polynomial curve.
The resolution is 16 bit increments/revolution per ms
2
.
122.20
Maximum deceleration offset
The value of this parameter in Inc/ms
2
specifies the maximum deceleration of the overlaid
compensating movement during the active operation by which the drive overlays the poly-
nomial curve.
The resolution is 16 bit increments/revolution per ms
2
.
1 bit
15 bit
16 bit
Sign
Revolutions