4.8
4.8.10.3 Vibration damping
Vibrations can occur in the controlled operation during low speed. These vibrations can
be damped with an additional speed set value. Here the high-frequency component of the
Iq-I term is filtered and added to the speed set value.
Figure 211:
Control diagram of the vibration damping
The I-term is guided through a slow filter (
) and a fast filter (
) and the
difference is then multiplied by a damping factor (
). This value is added to the
speed set value.
4.8.10.4 Motor diagnosis
In general the motor diagnosis checks if the notch position search with injection, the set
frequency (
), the amplitude (
) works and
therefore as well if a motor can be operated encoderless with injection. For this, the highly
frequent voltage is injected in the motor and thereby the electrical angle is slowly in-
creased by discrete steps. Then, the resulting demodulated signal is assigned to the an-
gle in ProDrive (see figure) and can be evaluated. The motor diagnosis is started via the
bit 4 of
d
-
+
(P133.55)
Iq-I part (P47.22)
Tfast (P133.58)
Tslow (P133.59)
nset (P18.21)
nact (P18.22)