5.5
1054
DSP Timeout Error: DSP does not
write the PWM Pot Registers in time, 3
times within 100 ms
DSP Timeout Error: DSP does not write the PWM Pot Registers in
time, 3 times within 100 ms
Pulse block
1055
DC link voltage chopper threshold (DC
link voltage max-30V) exceeded
The chopper threshold (DC link voltage Max-30V) was exceeded
during DC link voltage monitoring
No response
1056
Performance element 24 V Fail
When the 24V supply voltage drops below a specific threshold the
FPGA will activate a corresponding error bit in its status and block
the pulses.
Pulse block
1057
15 V fail - power cycle required
The 15 V power supply failed.
Pulse block
1066
SS1 stop forced by SAF module
If SS1 function is activated on SAF-002/-003 module and an appro-
priate error occurs, the SAF module forces the SS1 stop function on
the controller.
No response
1100
Drive manager general error pulse
enable
Drive is enabled and the pulses are inhibited without an accordant
error message.
Pulse block
1106
Drive operation mode not allowed with
this motor operation mode
Drive operation mode not allowed with this motor mode operation
mode. error caused when changing from state 3 to 4.
m
Effect
Drive is not started
m
Error reset
Error can be reset
Pulse block
1107
In this operation mode it is possible to
change to operation mode 4
In this operation mode it is possible to change to operation mode 4.
No online change possible e.g. from speed control to find notch posi-
tion.
No response
1300
Memory organization is faulty.
No response
1301
Invalid trigger configuration (both
edges)
Invalid trigger configuration in the ring buffer. Triggering to both
edges is not possible.
No response
1302
no Trigger ID entered
no Trigger ID entered
No response
1303
no ID to read out data
no ID to read out data
No response
1304
no permission to read out data
No response
1305
No record for channel and axis
No record for channel and axis
No response
1400
Error while loading or saving the data
record
Error while loading or saving the data record
Pulse block
1401
No valid parameter file found
No valid parameter file found
Pulse block
1402
CRC in parameter file not correct
CRC in parameter file not correct
Pulse block
1403
Invalid data record number indicated
for DSV command
An invalid data record number was indicated for a data record com-
mand.
The error is reported when an attempt is made to switch to a non-
existing data record, delete the active data record or copy the values
from a non-existing data record.
No response
1500
uBlaze Software has a critical error
It was an critical error and µBlaze Software is no longer functional
No response
1501
If there is no response from the slave
(HPI-Buffer Initialization)
Slave did not respond within specified time.
Master Ident Code = 0xDEADBEEF
Slave Ident Code = 0xBEEFDEAD
No response
1502
Message length is greater than HPI
Buffer
Message length is greater than HPI Buffer
No response
1503
Access to HPI wrong channel
Access to the wrong (non-existent) HPI-Channel
No response
1504
HPI Channel was not initialized
First Access to the HPI-channel was early as the initialization.
No response
1505
HPI buffer is empty
HPI buffer has no user data available.
No response
Error
num-
ber
Brief error text
Error description
Default set-
ting for
Error